Skip to content
Why Group
All companies

Why Inc. R&D · Tokyo, Japan

Denka Platinum: Eliminate High-Frequency Electrical Noise. Cut Losses. Protect Critical Assets.

Denka® Platinum Plates are passive, clip-on Ni-Zn ferrite-ceramic High-Frequency Passive Filters (150 kHz–30 MHz) engineered to attenuate conducted emissions from VFDs, solar inverters, rectifiers, and switch-mode power supplies — without rewiring or downtime.

Power QualityHF Passive FilterAsset ProtectionEnergy Efficiencyy-denka.com
Energy reduction
8–15%
Typical reduction in specific energy consumption (kWh/ton) across industrial installations — up to 20%.
Targeted band
150 kHz–30 MHz
The CISPR 11 conducted-emission band, where conventional IEEE 519 harmonic filters do not operate.
Attenuation per plate
13–15%
Peak high-frequency voltage attenuation per plate (25–30 MHz), independently verified at KU Leuven / EnergyVille.
Facilities
100+
Field-proven worldwide across cement, manufacturing, ceramics, and commercial plants, with payback under 1.5 years.

About the company & technology

A critical blind spot in modern industrial power systems

Developed by the R&D Department of Why Inc. (Tokyo, Japan) under the leadership of Executive Chairman Dr. Alaa Alyaman, Denka® addresses a critical blind spot in modern industrial power systems: high-frequency conducted emissions.

While traditional power-factor correction capacitors and low-order harmonic filters manage distortion below 2.5 kHz, fast-switching power electronics (VFDs switching at 2–16 kHz and SMPS at 20+ kHz) inject steep voltage edges (dv/dt) that generate conducted electromagnetic noise well into the MHz range.

Denka® HF Passive Filters clip directly onto existing phase conductors to absorb this high-frequency energy at the source.

The problem

The hidden cost of HF distortion

  • 01+19%

    Motor losses & thermal feedback

    Converter-generated HF harmonics increase total induction motor losses by 8.7% to 19%, raise iron losses under load by 29%, and elevate winding temperatures by ≈ 8 °C. Each 1 °C rise in a 37 kW motor adds ≈ 41 W of secondary losses.

  • 02+33%

    Transformer & cable degradation

    Inverter HF harmonics raise distribution transformer eddy-current losses by up to 33% and accelerate insulation ageing by 22%. In cables, the skin effect confines 30 MHz currents to a 0.012 mm outer layer (versus 9.2 mm at 50 Hz), spiking AC resistance.

  • 0351%

    Premature bearing & insulation failure

    Every 10 °C temperature rise halves electrical insulation life. Meanwhile, bearings account for 51% of motor failures — driven in VFD-fed motors by HF common-mode currents discharging through bearings and causing EDM pitting and fluting.

  • 04

    Control & metering interference

    High-frequency conducted emissions circulate locally between nearby equipment and filter capacitors, causing nuisance RCD breaker trips, PLC and smart-metering disruptions, and LED flicker.

How it works

How the HF Passive Filter works

  1. 01

    Zero impact on 50/60 Hz fundamental power

    Engineered from a Grade DT400L Ni-Zn ferrite-ceramic composite (μ(ω) = μ′(ω) − jμ″(ω)), the real permeability component (μ′) dominates at 50/60 Hz, adding negligible reactance so line power passes unaffected.

  2. 02

    Loss-dominated HF absorption (150 kHz–30 MHz)

    Across the CISPR 11 high-frequency band, the imaginary loss component (μ″) rises sharply. The plate acts as a frequency-dependent resistor, absorbing HF magnetic-field energy around the conductor and dissipating it as a minuscule amount of heat (≤ 0.4 °C self-heating).

  3. 03

    Dual-point clip-on protection

    Installed with zero rewiring or galvanic contact at the Distribution Level (breaker outputs feeding VFDs, rectifiers, and PV inverters) to stop network propagation, and at the Motor Level (drive-output cables) to block common-mode bearing currents.

Specifications

Technical specifications

FunctionPassive high-frequency conducted-noise filter (complements IEEE 519 filters)
VersionDenka® Platinum Plate (Black)
MaterialSintered Ni-Zn ferrite-ceramic composite (Grade DT400L)
Dimensions & weight50 mm × 25 mm × 3.5 mm · approx. 21 g per plate
Design band150 kHz to 30 MHz (CISPR 11 conducted-emission band)
Lab-verified attenuationBroadband 1–30 MHz; 13–15% (≈ 1.2–1.4 dB) per plate at 25–30 MHz (KU Leuven)
Self-heating & isolation≤ 0.4 °C under HF absorption · high-resistivity ceramic · no galvanic contact
Safety & maintenanceZero maintenance · non-radioactive, asbestos-free, halogen-free, RoHS compliant

Evidence

Verified case studies & lab validation

A selection of independently measured results. Many more case studies — across industries and countries — are available upon request.

  • Laboratory validation

    13–15%

    KU Leuven / EnergyVille (Belgium)

    Tested by the Power Electronics Research Group using an Agilent 4294A precision impedance analyzer across 1–30 MHz, confirming frequency-dependent HF voltage attenuation peaking at 13–15% per plate at 25–30 MHz.

  • Heavy industry

    −7.0%

    Cleopatra Cement Factory (Egypt)

    Independently measured by SGS on raw-mill induction drives: a 7.0% reduction in specific energy consumption (46.88 → 43.76 kWh/t) and a 59% reduction in power-draw variance.

  • Manufacturing

    −11.5%

    GSF Industrial Facility (Egypt)

    An 11.5% plant-level reduction in specific power consumption (78.69 → 69.61 kW/t), true power factor improved from 0.94 to 0.96, and full payback in under 1.5 years.

  • Ceramics & solar

    24.5% → 9.8%

    Saj Ceramics (Kenya, with BEST Energy)

    Site observations recorded current distortion (THDᵢ) on Glaze Prep Mill 8 dropping from 24.52% to 9.76%, and on gasifier pump circuits from 84.89% to 54.11%.

Diagnostic & M&V protocol

Every deployment is engineered and verified

Using IPMVP Option B/C and ASHRAE Guideline 14 standards, in five steps:

  1. 01

    HF spectrum survey

    On-site 2 kHz–30 MHz RF current probe sweep via portable spectrum analyzer.

  2. 02

    Thermal baseline

    Calibrated infrared thermography of terminals, cables, and motor boxes.

  3. 03

    Power-quality baseline

    Class A logging of THDᵢ, THDᵥ, and true power factor.

  4. 04

    Energy-to-production regression

    Logging active kWh against production tonnage over a full cycle.

  5. 05

    Post-installation A-B-A verification

    Repeating all baselines after clip-on installation to certify net energy recovery.